Fire-Rated Partition FSC02 Endorsement Singapore

Compartment walls, protected shafts to lifts, staircases and services, and fire-rated enclosures to steel, firefighting systems and building services.

Direct answerFire-rated partitions — compartment walls and protected shafts (Table 11A items 4.1 to 4.3) and fire-rated enclosures (items 7.1 to 7.3) — require a valid CoC and a DoC. For FSC02, the Appropriate QP checks that wall height, framing, board layers, joints, openings and penetrations match the certified system.

Last reviewed: 24 September 2026 · Primary reference: SCDF Fire Code 2023, Chapter 11 and Table 11A · Prepared by PE Consultants Pte Ltd

Partitions and enclosures covered

Table 11AProduct
4.1Compartment wall
4.2Protected shaft — lift
4.3Protected shaft — staircase or services
7.1Protection to steel structure (fire-rated enclosure or spraying material)
7.2Protection to firefighting system
7.3Protection to building services
12Fire-rated glass block / glass partition — see SCDF regulated fire safety products

Fire-rated partition FSC02 checks

  • CoC scope for wall height and fire-resistance period
  • Stud gauge, spacing and deflection head
  • Board type, layers and fixings
  • Joint treatment and staggering
  • Door and glazing openings (doors are separately certified with labels)
  • Services penetrations — see fire stopping and fire-rated collars
  • Junctions with slabs, ceilings and external walls
  • Project DoC and site photographs

Fire-rated glass partitions need the glass type, frame and maximum pane size to fall within the CoC. Enclosures to steel may alternatively be protected by an intumescent coating system.

QP verification before FSC02

  1. Regulated and compliant product — the product falls within a Table 11A category and is certified for that use.
  2. Valid CoC — current, not withdrawn, suspended, terminated or superseded, verified in the Certification Body’s directory.
  3. Exact match to the CoC — brand, model, composition, thickness, configuration and manufacturer match the CoC and appendix.
  4. Representation of compliance — the DoC, serial label or certified mark required for that product is present and traceable.
  5. Correct installation — installed in accordance with the certified system and the approved fire safety design.

FSC02 endorsement is subject to review of the product documentation, certification scope, installation details and the QP’s professional assessment.

Our FSC02 work process

  1. Submit product and project informationSend the project details, CoC, DoC and product literature to pe@qp.sg or through the enquiry form.
  2. Review the product category under SCDF Table 11AWe confirm the regulated product category, the current Table 11A reference and whether FSC02 applies.
  3. Check the CoC, test reports, system scope and validityCoC number, issue number, holder, model and scope are checked against the Certification Body’s directory.
Ready to start? Send your CoC and product details to pe@qp.sg
  1. Check the DoC, serial label or certified markWhere applicable, we confirm the representation of compliance matches the certified product and the project.
  2. Inspect or verify the installed productQP site inspection or verification of the installation against the certified system and approved fire safety design.
  3. Prepare the FSC02 endorsement and supporting documentsSubject to satisfactory review, we prepare the FSC02 endorsement and supporting submission documents.
Send your CoC and product details to pe@qp.sgRequest FSC02 Assessment

Frequently asked questions

Do compartment walls and protected shafts require FSC02?

Compartment walls and protected shafts (Table 11A items 4.1 to 4.3) are regulated fire-rated partitions requiring a CoC and DoC, and are identified in the Annex C list for endorsement by the Appropriate QP. The installed wall, including height, framing, board layers, joints, openings and penetrations, must match the certified system.

Can a product be used if its CoC model differs from the installed model?

Generally no. The installed product must match the CoC exactly — brand, model, composition, thickness, density, configuration and manufacturer. A different model, revised build-up or alternative manufacturer needs its own CoC coverage, or a revised CoC issued by the Certification Body. The QP cannot extend a CoC’s scope by professional judgement. See CoC and DoC review.

Can a contractor substitute a different fire-rated product during construction?

Only with care. A substitute must be a regulated product with its own valid CoC covering the exact model and configuration, the required DoC or labels, and it must suit the approved fire safety design. Changes to tested assemblies, supporting structure or penetration details may require design review. PE Consultants provides product substitution review before the change is made.

Request FSC02 Assessment

Send your CoC, DoC, product details and installation information to PE Consultants Pte Ltd. FSC02 endorsement is subject to review of the product documentation, certification scope, installation details and the QP’s professional assessment.

Email: pe@qp.sg  |  WhatsApp: +65 9800 4385